Product Description
🔥 Offer!
If you purchase this set together with your Creative machine, we will pre-wire the spindle for you using approximately 5 meters of shielded cable – free of charge.
Please note:
The default setup includes manual start/stop control for the spindle.
If you prefer automatic start/stop via the control board, let us know – we’ll provide the instructions to connect it yourself.
Fits our Raw Creative machines. When you purchase this product you will also receive instructions on how to connect the spindle to the VFD and circuit board.
Spindle
The spindle is of the ER16 type and can have inserts between 1-10mm.
Input Voltage | 220V Single Phase or 3 Phase |
Speed | 8000-24000R/min |
Power | 1500W |
Frequency | 400Hz |
Cooling System | Air Cooling |
Weight | 3.95kg |
OD | 80mm |
Current | 5.6A |
ER16 collet chuck | |
Grease Lubrication | |
Run out of less than 0.005mm |
Frequency converter (VFD)
1. Technology Criterion
Items | Criterion | |
Performane | Frequency range | 0~600Hz |
Precision of output frequency | 0.01Hz | |
Distinguish rate of setting frequency | Digital setting: 0.01Hz. | |
Analog setting: AD switch precision for one in thousand,linearity for +-5% | ||
Speed range | 1:100 | |
Overload capability | E100S series:150%rated current 60s;180%rated current 2s. E100T series(G model): 150%rated current 60s;180%rated current 2s. | |
E100T series(P model): 120%rated current 60s;150%rated current 2s. | ||
Remark:may obtain the informations of model and power in ldquod1 function groupsrdquo. | ||
Control Mode | Open-loop simple vector control | |
Torque boost | Manual torque can be adjust; Auto-Torque upgrade the whole frequency band. | |
Start up Torque | when0.5Hz, rated torque for 150%. | |
Function descriptions | Acc and Dec time | 0.1~3200.0s |
Jog function | Jog frequency:0.00~50.00h z; | |
Standard functions | Simple vector control, torque boost, automatic slip compensation (rev gain) , stop for DC braking,Restart after power off instantaneous,auto fault reset, control over-current when accelerating speed,multi-step speed 4 run,traverse frequency function applies to textile,closed loop PID control | |
Run rule | 3kinds control mode:keyboard control,analog terminal control,serial communication control. | |
Frequency Source Selection | Digital setting,analog voltage setting,analog current setting,the serial communication port setting; can be combined through a variety of ways to switch. | |
Input | 4digital input terminals, as many as 13 kinds of custom features, is compatible with the active NPN input; | |
Terminals | Two analog input terminals, can receive a voltage signal (0 ~10V), or current signal (4 ~ 20mA); | |
Output | 1 relay output, up to 6 kinds of user defined functions;11 open-collector output, 6 user defined functions; | |
Terminals | 1 analog output, 4 kinds of user defined functions; can export voltage signal (0 ~ 10V). | |
Protection functions | Overvoltage,undervoltage and external fault,overcurrent,overheating,overload | |
Environment | Installation place | Indoor, Altitude of less than 1 km, clean, non-corrosive gases and no direct sunlight |
Temperature | -10℃ ~ +40℃( Inverter will be derated if ambient temperature exceeds 40degC.) | |
Humidity | 20%~90%RH(without dewfall) | |
Vibration | Less than 0.5g | |
Storage | -25℃~+65℃ | |
Temperature |
2. Product Feature:
1. E100 series inverter uses a simplified vector control technology, with extensive application of functional blocks.
2. Can be the whole frequency band of torque automatic compensation, to compensate for the output torque to meet the user requirements for high torque; to improve the dynamic response and motor control features.
3. Have a proportional, integral and differential (PID) control function of the closed-loop control, can be used for process control ,such as constant pressure water supply.
4. Built-in the function of the textile-specific swing band.
5. Fast current limit (FCL) function, to avoid undue running trip.
6. Built-in DC injection braking.
7. Acceleration / deceleration ramp features have a programmable smoothing function.
8. Prevent the speed lose during over-voltage, in running the inverter automatically limit the increase of DC bus voltage.
9. Fault and fault query monitoring features.
10. Built-in serial communication interface, using standard modbus communication protocol.
3. Installation Environment
1. There are vents or ventilation devices in indoor places.
2. Ambient temperature -10 C ~ 40 C. If the ambient temperature is bigger than 40 C, but lower than 50 C, may take off the cover board of inverter or open the front door cabinet, in order to reduce temperature.
3. Try to avoid high temperature and wet places, humidity less than 90%, and without dewfall.
4. Avoid direct sunlight.
5. Away from air pollution such as flammable and corrosive gases, liquids.
6. No dust, floating particles of fiber and metal.
7. It is not allowed that the inverter falls down or suffers from fierce impact or the inverter installed at the place that vibration frequently.
8. Keep away from the electromagnetic radiation source.